Skip to content

6.19.0

If your product is installed and working without any issues, we strongly recommend that you do not update your software/firmware.

Please send questions and comments about this document to [email protected].

Release Date: 2026-11-06

New Features

Improvements

  • (BX-4KU) The Warp and Blend dialog now remembers the grid line thickness when reopening the dialog.
  • (BX-4KU) Grid snap in the Warp and Blend dialog now uses the output divisions and follows the perspective warp.
  • (BX-4KU) Made usability improvements to the Warp and Blend dialog, and made its canvas larger.
  • (BX-4KU) Warp can now be applied to video output 1 in quad output mode.
  • (Product File Creator) Product File Creator no longer allows operator characters (such as + - * / < > = ! &) in variable or parameter names where they are invalid.
  • (Product Files) Updated Norxe Unify product file to version 2.0. The JSON and ASCII protocols are now in one product file.
  • (WinScript) The script import tool now shows its messages while it converts a script, not only at the end.
  • (WinScript) The WinScript splash screen now shows the version number.
  • (WinScript) WinScript now saves scripts faster.

Bug Fixes

  • (All Products) Fixed controller crash that could occur when stopping a timed sequence that has a Loop event looping itself.
  • (All Products) Fixed incorrect output from the product file sprintf function. This occurred when a comma in the value list had no space after it, or when a value was blank.
  • (All Products) Fixed issue where reading an invalid EtherNet/IP PLC tag could cause other valid tag reads to fail if they were bundled in the same message.
  • (All Products) Fixed issue where an invalid ASCII command received over TCP caused the controller to reject all later commands on that connection.
  • (All Products) Fixed issue where product files discarded the characters that remained after a regular expression message matched in a TCP stream. Other regular expression messages can now match these characters.
  • (All Products) Fixed issue where the controller used overly short timeouts when connecting to TCP devices, resulting in reconnections on high-latency networks.
  • (All Products) Fixed issue where the controller generated SMPTE at startup after changing SMPTE from Read or Generate on Startup to Disabled (requires setting SMPTE to Disabled in WinScript again).
  • (BX-4KU) The video output now shows a black frame during warp updates to prevent a flash when warp points are moved.
  • (BX-4KU) Fixed issue where the BX-4KU applied an incorrect shape for some warps made in the Warp and Blend dialog.
  • (BX-4KU) Fixed issue where the BX-4KU rejected 23.976 as the system frame rate.
  • (BX-4KU) Fixed sync issues that could occur when the video output frame rate was different from the script frame rate.
  • (BX-4KU) Fixed visual artifacts outside the canvas of the Warp and Blend dialog when dragging a selection box or warp point.
  • (BX-4KU) Improved reliability while uploading or changing media files, especially during playback.
  • (BinloopX) Fixed issue where the live log sometimes showed erroneous timeout errors after executing certain events.
  • (Product Files) Updated Weigl ProCommanderAX product file to version 1.5. Fixed the "Get Specific Show Status" event, and status values now show in variable watches.
  • (RidePlayer) Fixed issue where a RidePlayer set to read SMPTE would generate SMPTE instead.
  • (RidePlayerX) Fixed issue where the "Get Version" event did not set the "Version" device variable (requires updating the product file in the script).
  • (V16X/V4X) Fixed issue where a script name of 39 or more characters showed as a blank entry in the front panel Script menu.
  • (V16X/V4X) Fixed issue where the DMX output could send random values at startup with certain devices.
  • (V4X) Fixed issue (introduced in 6.17.0) where the factory default screen was missing from the front panel display.
  • (WinScript) Fixed crash that could occur when deleting an event that was in a timeline group.
  • (WinScript) Fixed crash that could occur when editing the properties of a third-party device array.
  • (WinScript) Fixed crash that could occur when using Update From Local Files with subfolders in the Media window.
  • (WinScript) Fixed issue on macOS where the X button did not close the Connection Manager.
  • (WinScript) Fixed issue on Windows where the open and save dialogs always started in the Documents folder.
  • (WinScript) Fixed issue where changing a device type could cause issues with built-in device variables for that device.
  • (WinScript) Fixed issue where editing an event time in grid view moved the sequence window to the top.
  • (WinScript) Fixed issue where media events would not show their new length until the timeline window is re-opened.
  • (WinScript) Fixed issue where some serial settings, such as baud rate, went back to their default values when opening the device dialog again.
  • (WinScript) Fixed issue where the Find window showed the wrong value after a replace when the new value contained the old value.
  • (WinScript) Fixed issue where the Locale settings showed Orlando coordinates as defaults, but the firmware used 0 Lat, 0 Long.
  • (WinScript) Fixed issue where the script import tool would become unresponsive while converting scripts.
  • (WinScript) Fixed issue where the selected devices list showed the model name instead of the device name for some devices.
  • (WinScript) Fixed issue where WinScript for macOS showed a lower controller utilization than WinScript for Windows for the same script.
  • (WinScript) Fixed issues on macOS where the Connection Manager sometimes did not find devices, and where WinScript asked for folder access each time it started.
  • (WinScript) Fixed issues with using device references in Live Mode and ShowTouch.
  • (WinScript) When installing an older version of WinScript over a newer version, the Alcorn McBride product files are now replaced with the older versions.
  • (WinScript) The Connection Manager no longer shows a green check mark for script compatibility when the script has unsaved changes.
  • (WinScript) WinScript no longer asks to resize pages when making a new panel.