6.15.0
If your product is installed and working without any issues, we strongly recommend that you do not update your software/firmware.
Please send questions and comments about this document to [email protected].
Release Date: 2025-07-25
New Features
- (All Products) Added the ability to query device variables for a controller without knowing the device's name.
- (All Products) Added support for Alcorn command protocol over TCP.
- (All Products) Added suport for new "Else If" event.
- (BinloopX/V16X/V4X/RidePlayerX) Added an uptime counter to the front panel system menu which displays the amount of time elapsed since startup.
- (BinloopX/V16X/V4X/RidePlayerX) Added the ability to filter the types of operational log messages that are stored to internal storage.
- (BX-16A/RidePlayer/RidePlayerX) Added equal power fade option for audio fades.
- (BX-16A/RidePlayer/RidePlayerX) Added per-channel inversion to DSP.
- (BX-4KU) Added Rec. 2020 output support.
- (Product File) Added product file for Norxe projectors.
- (ShowTouch) Added the ability to choose whether sliders will jump to a touched position of whether they must be dragged.
Improvements
- (All Products) Clarified documentation around the range of values produced when generating random numbers in a script.
- (All Products) Removed live log message that was generated whenever an event condition was false at the time of event execution.
- (BX-4KU) Sped up scroll speed of clip names on the module screen.
- (RidePlayer) Improved ability to verify media when dealing with large audio files.
- (WinScript) Improved performance when using large scripts.
- (WinScript) Automatically open the device media folder when using the "Add from Device" feature instead of needing to navigate to the correct folder manually.
- (WinScript) Improved consistency of transport control naming in WinScript for SMPTE sequences.
- (WinScript) Allow creation of a BinloopX script without any modules.
- (WinScript) Changed name of "on power-up" triggers to be "on start-up" to clarify that a power cycle is not required.
- (WinScript) Renamed Help menu "Help Topics" to "User's Guides" for consistency.
- (WinScript) Clarified trigger summary text for "on set" and "on change" triggers.
Bug Fixes
- (All Products) Fixed issue where multiple devices of the same type occasionally overwrite one another's data with parsed values when event responses are received at the same time.
- (All Products) Fixed issue storing the result of an "Eval" event to a timecode variable.
- (All Products) Fixed issue preventing the use of bit aliases in "Eval" events.
- (All Products) Fixed issue with running sequences being restarted if an offset is used regardless of whether the sequence is configured to allow restarts or not.
- (BinloopX) Fixed issue where cuing a video in a timeline to an output that was already playing would stop the previous video.
- (BX-4KU) If a seamless clip transition isn't possible because the new clip uses a different encoding than the playing clip, the BX-4KU will still play rather than ignore the new clip. A black flash may occur during the transition.
- (Product File) Fixed issue with "Get Input Status" in Weigl product files.
- (Product File) Fixed various issues with ETC Paradigm product file.
- (ShowTouch) Fixed issue with screen rotation not working on some hardware.
- (ShowTouch) Fixed the ability of sliders to work with percent variable types.
- (ShowTouch) Fixed issue with text sometimes appearing in the wrong position.
- (V16ProS) Fixed missing SMPTE/LTC menu on front panel.
- (WinScript) Fixed issue where device dropdown in device variables view would not update unless the window was closed and reopened.
- (WinScript) Prevent reordering and renaming of built-in device variables, which can cause strange behavior when multiple devices of the same type exist in a script.
- (WinScript) Fixed issue where WinScript would appear unresponsive after right-clicking an event inside the resource tree.
- (WinScript) Fixed issue that would cause local media path information to be deleted from a script if the local media files were not found.
- (WinScript) Fixed issue where inpoints could not be used for media events in a logical sequence.
- (WinScript) Fixed issue with toolbar extension button not being visible in dark mode.
- (WinScript) In playback dashboard, moved location of VU meter to clarify that sample metering now takes place after DSP is applied and not before.
- (WinScript) Fixed issue where deleting a timeline group would delete events without warning.
- (WinScript) Fixed issue where event wizard would sometimes open off-screen on macOS.
- (WinScript) Fixed sporadic warning message about being unable to write to a temporary ami file on Windows.
- (WinScript) Fixed issue that allowed a timed sequence to loop itself.
- (WinScript) Fixed issue with variable min and max settings being ignored for initial values.
- (WinScript) Fixed crash that could sometimes occur when closing the appearance window of Touch items.
- (WinScript) Fixed issue with "Volume Sliders Require Live Mode" text not going away once connected in Live Mode.
- (WinScript) Fixed issue where integers were not accepted as parameters for "Set Mix" events.
- (WinScript) Fixed issue with variables whose names start with underscore ("_") not being supported in "Eval" and "If" statements.